PNC .........................................
Serial number ...........................
Built-in hobs
Only use the built-in hobs after you assemble the hob
into correct built-in units and work surfaces that align to
the standards.
Connection cable
• For a single phase or two phase connection use the
following (or higher) mains cable type: H05V2V2-F T
min 90°C.
• To replace the damaged mains cable use the
following (or higher) mains cable type: H05V2V2-F T
min 90°C. Speak to your local Service Centre.
Building In
min. 55 mm
min. 650 mm
550 mm
min. 100 mm
30 mm
470 mm
A. supplied seal
B. supplied brackets
Caution! Install the appliance only on a
worktop with flat surface.
Possibilities for insertion
The panel installed below the hob must be easy to
remove and let an easy access in case a technical
assistance intervention is necessary.
Kitchen unit with door
min 20 mm
(max 150 mm)
30 mm
60 mm
B
A
A. Removable panel
B. Space for connections
Kitchen unit with oven
The electrical connection of the hob and the oven must
be installed separately for safety reasons and to let
easy remove oven from the unit.
Technical data
Cooking zones specification
Cooking zone Nominal Power (Max heat setting) [W] Cooking zone diameter [mm]
Left front 2000 180
Left rear 1000 145
Right front 1500 145
Right rear 1500 180
For optimal cooking results use cookware not larger
than the diameter of the cooking zone.
17