connectors into the correct oven sockets. The design of
the plugs and sockets prevents incorrect connections.
Building In
589
598
594
114
19
21540
570
558
min. 550
20
600
min. 560
3
9
Securing the appliance to the cabinet
Electrical installation
The manufacturer is not responsible if
you do not follow the safety precautions
from the Safety chapters.
This appliance is supplied without a main plug and a
main cable.
Cable
Cable types applicable for installation or replacement:
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-F, H05 V2V2-
F (T90), H05 BB-F
For the section of the cable refer to the total power on
the rating plate.
Connecting the terminal board
The appliance has a six-pole terminal board. The
jumpers (bridges) are set for operation on a 400 V
three-phase with a neutral wire.
1 = 45 mm
2 = 45 mm
3 = 60 mm
4 = 60 mm
= 70 mm
1 2 3 4 5
L 1 – 2 – 3 = phase cables
N 4 = neutral cable
= earth cable
If the mains voltage is different, rearrange the jumpers
on the terminal board (refer to the connection diagram
below). Connect the ground cable to the terminal. After
you connect the supply cable to the terminal board,
attach it with a junction clamp.
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
230V 3~
230V 1~
400V 2N~
400V 3N~
L1
L1 N
L2
L1 N
N
L2
L3
L1 L2 L3
PE
PE
PE
PE
18